13: I/O Configuration
The I/O tab in ACEmanager is applicable across all Sierra Wireless
AirLink devices that feature I/O ports.
You can use the input/outputs on AirLink devices to generate reports
based on a threshold being crossed, a switch being open or closed,
or the number of times a switch has changed its state.
Use the Events Reporting screen to configure reports. (See Events
Reporting Configuration on page 207.) Use the I/O screen to view the
current state of the analog and digital inputs, to turn the relays on and
off, and to configure the units you want used in the reports based on
analog inputs.
Analog inputs
Analog inputs monitor a voltage range in small increments. This
allows you to monitor equipment that reports status as an analog
voltage. Examples include:
• Power supply voltage
• Temperature, weight, volume, flow represented as voltage
• An incremental gauge with a voltage output
• Vehicle battery voltage
Using Event Reporting, you can create event thresholds, which when
crossed (either higher or lower) generate a report to a defined
external system. See Events Reporting Configuration on page 207.
The raw data for the changes being monitored is in volts, but you can
use the I/O Configuration screen in ACEmanager to convert voltage
to the desired units of measurement.
Digital inputs
Digital inputs monitor contact closures on a switch. This allows you to
monitor changes such as:
• When a door or latch is open or closed
• When a container is full or empty
• When a switch or valve is open or closed
• The level of fuel in a vehicle (connected to an on/off sensor)
• When the trunk of a vehicle is opened or closed