Events Reporting Configuration
Rev 1 Oct.13 219
· Enable for IP Packets Received—The number of IP packets received from
the cellular network since last reset
· Enable for Host IP Packets Sent—The number of IP packets sent from the
network between the AirLink device and the connected device(s) since last
reset
· Enable for Host IP Packets Received—The number of IP packets received
from the network between the AirLink device and the connected device(s)
since last reset
• Misc Data
Miscellaneous Data includes temperature rates and other information that
does not fit in the other categories
· Enable for Power In—The voltage level of the power coming in to the
AirLink device at the time of the report
· Enable for Board Temperature—The temperature of the internal hardware
of the AirLink device at the time of the report
· Enable for Host Comm State—The signal level between the AirLink device
and the connected device(s)
· CDMA HW Temperature—The temperature of the internal radio module
· CDMA PRL Version—PRL version used by the AirLink device
· CDMA EC/IO—The quality of the signal from the cellular CDMA network
· GSM EC/IO—The quality of the signal from the cellular GSM network
· Cell Info—The cellular network cell information for the AirLink device
Note: For each group you can enable individual fields.
Relay
The relay outputs on the AirLink device I/O port can be used to cause an external
action.
• 1—Relay 1—Open
• 2—Relay 1, Inverted—Closed
The relays are capable of switching small loads. If you need a stronger signal,
such as to open a door lock, connect the AirLink device’s relay to a stronger
solenoid relay that has enough power to cause the desired effect.
Configure Events
To configure events,
1. Enter an Event Description. The event description will be displayed in the
Events group in the left hand side panel.
2. Select any action and click Add Action. Then select any Action Type and
configure accordingly.
3. Click Save and the action will be displayed in the Available Actions menu.