Operation
6.3 Basic information about the drive system
Drive converter cabinet units
196 Operating Instructions, 10/2008, A5E00288214A
%2%LQHFWRURXWSXW
6LJQDOVRXUFH
%,%LQHFWRULQSXW
6LJQDOVLQN
'ULYH
'ULYH
2))
2))
2))
2))
2))
2))
',
U
;
9
S>&@

S>&@


S>&@

S>&@


Figure 6-8 Connection of OFF3 to several drives (example)
BICO interconnections to other drives
The following parameters are available for BICO interconnections to other drives:
r9490
Number of BICO interconnections to other drives
r9491[0...15]
BI/CI of BICO interconnections to other drives
r9492[0...15]
BO/CO of BICO interconnections to other drives
p9493[0...15]
Reset BICO interconnections to other drives
Binector-connector converters and connector-binector converters
Binector-connector converter
Several digital signals are converted to a 32-bit integer double word or to a 16-bit integer
word.
p2080[0...15] BI: PROFIdrive PZD send bit-serial
Connector-binector converter
A 32-bit integer double word or a 16-bit integer word is converted to individual digital
signals.
p2099[0...1] CI PROFIdrive PZD selection receive bit-serial
Fixed values for interconnection using BICO technology
The following connector outputs are available for interconnecting any fixed value settings:
p2900[0...n]
CO: Fixed value_%_1
p2901[0...n]
CO: Fixed value_%_2
p2930[0...n]
CO: Fixed Value_M_1
Example:
These parameters can be used to interconnect the scaling factor for the main setpoint or to
interconnect an additional torque.