Velocity Edge GX440 Operations Instructions Page 191

  • Download
  • Add to my manuals
  • Print
  • Page
    / 530
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 190
Operation
6.3 Basic information about the drive system
Drive converter cabinet units
Operating Instructions, 10/2008, A5E00288214A
191
Copying the command data set (CDS)
Set parameter p0809 as follows:
1. p0809[0] = number of the command data set to be copied (source)
2. p0809[1] = number of the command data to which the data is to be copied (target)
3. p0809[2] = 1
Start copying.
Copying is finished when p0809[2] = 0.
Copying the drive data set (DDS)
Set parameter p0819 as follows:
1. p0819[0] = Number of the drive data set to be copied (source)
2. p0819[1] = Number of the drive data set to which the data is to be copied (target)
3. p0819[2] = 1
Start copying.
Copying is finished when p0819[2] = 0.
Copy motor data set (MDS)
Set parameter p0139 as follows:
1. p0139[0] = Number of the motor data set that is to be copied (source)
2. p0139[1] = Number of the motor data set which should be copied into (target)
3. p0139[2] = 1
Start copying.
Copying has been completed, if p0139[2] = 0.
Function diagram
FP 8560 Command data sets (CDS)
FP 8565 Drive data set (DDS)
FP 8570 Encoder data set (EDS)
FP 8575 Motor data sets (MDS)