12 Daniel Mark III Ultrasonic Gas Flow Meters assembly
Section 2: Product overview Reference, Installation, and Operations Manual
August 2014 3-9000-743 Rev U
2.2.1 Daniel Mark III Ultrasonic Gas Flow Meters assembly
The Mark III electronics assembly consists of an upper explosion-proof Mark III housing and a
lower intrinsically-safe Mark III base unit assembly (see Figure 2-2). The user field I/O wiring that
enters the upper explosion-proof Mark III housing must be explosion-proof wiring as noted in
Section 3.3.5 and Section 3.3.6. None of the connections to this upper explosion-proof Mark III
housing are intrinsically safe.
The transducer cabling exiting from the lower intrinsically safe Mark III base unit is intrinsically
safe so that the user may perform maintenance on the transducers without the need to remove
power from the meter.
Upper explosion-proof housing
a Daniel Mark III Ultrasonic Gas Flow Meter CPU (Central Processing Unit) Board
a Field Connection Board (for making electrical connections)
a Daniel Mark III Ultrasonic Gas Flow Meter I.S. (Intrinsically-Safe) Interface Board
(permanently mounted on the CPU Board)
Option Boards (Series 100 Option Board or Series 100 Plus Option Board).
Figure 2-2 Daniel Ultrasonic Gas Flow Meter Mark III Electronics
Upper Explosion-Proof
Mark III Housing Assembly
Lower
Intrinsically-
Safe Mark III
Acquisition
Option
Boards
Board
CPU
Board
Assembly
Field
Termination
Board
I.S.
Interface
Board
Base Unit
Conduit
entries for
transducer
cabling