76 Communication settings
Section 3: Installation Reference, Installation, and Operations Manual
August 2014 3-9000-743 Rev U
Port B Driver Configuration
The serial communication Port B driver is configured via CPU Board switch banks S4, S5, and S7
and Field Connection Board switch bank S1.
Port B supports a special override mode which forces the port to use known communication
values (19200 baud, address 32). (Note that the protocol is auto-detected.) This mode is
expected to be used during meter commissioning (to establish initial communication) and in
the event that the user cannot communicate with the meter (possibly due to an inadvertent
communication configuration change).
The Port B communication override mode is entered by switching CPU Board S2-1 (switch
bank 2, position 1) from the OPEN position to the CLOSED position. Port B remains in the
override mode until either (1) the port configuration is changed (via software), (2) two minutes
has elapsed (at which time the port reverts to its current configuration), or (3) the S2-1 switch is
changed back to the OPEN position.
To configure Port B for RS-232 operation, set the switches as indicated in the table below (see
Figure 3-24 for switch bank locations):
Table 3-28 Port B RS-232 driver settings
Board Switch Position
CPU S4-1 RS232
S4-2 RS232
S5-2 FULL
S7-1 RS232
S7-2 RS232
Field Connection S1-5 TERM OFF
S1-6 TERM 0FF
S1-7 FULL DUPLX
S1-8 FULL DUPLX
It is the action of changing S2-1 from the OPEN to CLOSED position (not being in the CLOSED
position) that causes the override mode to be entered.