Reference, Installation, and Operations Manual Part Number 3-9000-743 Revision UAugust 2014DanielTM Ultrasonic Gas Flow Meters with Mark III Electroni
ii ContentsTable of Contents Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U 2.4 Electronic specifications ...
74 Communication settingsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev USerial Communication Port
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Communication settings 75To configure Port A for R
76 Communication settingsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UPort B Driver Configurati
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Communication settings 77To configure Port B for R
78 Communication settingsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UPort C Driver Configurati
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Frequency and Digital Output switch settings 793.5
80 Option Board analog inputs switch settingsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UFigur
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Option Board analog inputs switch settings 81Table
82 Option Board analog inputs switch settingsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UTable
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Series 100 Option Board analog output switch settin
Reference, Installation, and Operations Manual Table of Contents3-9000-743 Rev U August 2014Contents iii 3.6 Security seal installation ...
84 Series 100 Plus Option Board Analog Input switch settingsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Series 100 Plus Option Board Analog Input switch se
86 Series 100 Plus Option Board Analog Output switch settingsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-900
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Series 100 Plus Option Board Analog Output switch s
88 DHCP server switch settingsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U3.5.7 DHCP server sw
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014End cap security seal installation 893.6.1 End cap
90 Upper electronics housing to base unit security sealSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Transducer assembly security seal installation 913
92 Transducer assembly security seal installationSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Section 4: Optional features3-9000-743 Rev U August 2014Overview 93430Section 4: Optional features4.1
iv ContentsTable of Contents Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U 5.6.5 Startup page...
94 Obtaining optional keysSection 4: Optional features Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U4.1.2 Obtaining opt
Reference, Installation, and Operations Manual Section 4: Optional features3-9000-743 Rev U August 2014Optional Aga10 key (sound velocity calculation
96 Trial period (firmware v1.6X and below)Section 4: Optional features Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Communications 97531Section 5:
98 CommunicationsSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UDaniel MeterLi
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Communications 99Set Baseline W
100 Communications setupSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U5.2 Com
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Communications setup 101Ports A
102 Communications setup wizardSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Initial Ethernet communications
Reference, Installation, and Operations Manual Table of Contents3-9000-743 Rev U August 2014Contents v 6.1.14 Seniorsonic flow characterizations .
104 Ethernet initial connection stepsSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Ethernet initial connection step
106 Ethernet initial connection stepsSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Ethernet initial connection step
108 Ethernet PC, HUB, or LAN connectionsSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Connect a Mark III Meter to a LA
110 Serial port connections using RS-232 serial cableSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014RS-232 serial connection setup
112 RS-232 serial connection setupSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Re
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014RS-485 serial connection setup
vi ContentsTable of Contents Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev USection 7: Maintenance and troubleshooting 7.
114 RS-485 serial connection setupSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Re
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014RS-485 serial connection setup
116 RS-485 serial connection setupSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Re
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014RS-485 serial connection setup
118 Writing changes while connected to the meterSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Meter configuration setup wizard
120 Daniel MeterLink meter configuration overviewSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 201
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Daniel MeterLink meter configura
122 Configuration protectionSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UCon
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Configuration checksum value and
Reference, Installation, and Operations Manual Table of Contents3-9000-743 Rev U August 2014Contents vii C.4.2 Metrology - calibration equation p
124 Meter configuration using Daniel MeterLinkSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Meter configuration using Daniel
126 Meter configuration using Daniel MeterLinkSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Meter configuration using Daniel
128 Meter configuration using Daniel MeterLinkSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Meter configuration using Daniel
130 Meter configuration using Daniel MeterLinkSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Meter configuration using Daniel
132 Startup pageSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U5.6.5 Startup p
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Startup page 133 Figure 5-8 F
viii ContentsTable of Contents Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
134 Startup pageSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U• Live Analog•
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Startup page 135• Pressure expa
136 Startup pageSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UTo enable / ide
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014General Page 1375.6.6 General P
138 Frequency Outputs PageSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U• Con
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Frequency Outputs Page 1391. Fr
140 Current Outputs PageSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U5.6.8 C
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Current Outputs Page 141 Table
142 Current Outputs PageSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UMaximum
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Current Outputs Page 143Full sc
Reference, Installation, and Operations Manual List of Tables3-9000-743 Rev U August 2014List of Tables ixList of TablesTable 1-1 Gas Ultrasonic Met
144 HART® Output PageSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U5.6.9 HART
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014HART® Output Page 1451. From th
146 Meter Digital outputsSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U5.6.10
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Meter Corrections page 1475.6.1
148 Meter Corrections pageSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev Uc. Te
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Temperature and Pressure page 1
150 Temperature and Pressure pageSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Temperature and Pressure page 1
152 Temperature and Pressure pageSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Temperature and Pressure page 1
x List of TablesList of Tables Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UTable 3-20 J16 Port C ...
154 Gas Chromatograph Setup pageSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014AGA 8 Setup page 155h. Use whic
156 AGA 8 Setup pageSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U1. From the
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Continuous Flow Analysis page 1
158 Continuous Flow Analysis pageSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Set Baseline Wizard 1595.6.16 S
160 Process parameters and calibration configurationSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Update Time Wizard 161For contr
162 Calculated resultsSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U5.7.2 Cal
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Set calibration parameters 1635
Reference, Installation, and Operations Manual List of Tables3-9000-743 Rev U August 2014List of Tables xiTable 5-6 Serial Port A RS-485 Full duplex
164 Set calibration parametersSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U2
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Set calibration parameters 165D
166 Set calibration parametersSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UF
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Set calibration parameters 167W
168 Set calibration parametersSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UP
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Set calibration parameters 169P
170 Saving the meter configurationSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Re
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Maintenance logs and reports (Lo
172 Maintenance logs and reports (Logs/Reports Menu)Section 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Maintenance logs and reports (Lo
xii List of TablesList of Tables Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UTable 6-15 Gas Chromatograph Sim 2251 Reg
174 Maintenance logs and reports (Logs/Reports Menu)Section 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Log Format 1755.9.1 Log FormatM
176 Log FormatSection 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U• Chord Status, P
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Log Format 177Flow PressureIf t
178 Trend maintenance logs (Logs/reports Menu)Section 5: Startup and meter configuration Reference, Installation, and Operations ManualAugust 2014 3
Reference, Installation, and Operations Manual Section 5: Startup and meter configuration3-9000-743 Rev U August 2014Meter Archive Logs (Logs/Reports
180 Compare Excel Meter Configurations (Logs/Reports Menu)Section 5: Startup and meter configuration Reference, Installation, and Operations ManualA
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Measurement 18161PSection 6: Meter operationThe
182 MeasurementSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U Figure 6-2 Juniorsonic Measure
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Terminology 183636.1.1 TerminologyThe following
Reference, Installation, and Operations Manual List of Figures3-9000-743 Rev U August 2014List of Figures xiiiList of FiguresFigure 1-2 Baseline vie
184 Signal processingSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U6.1.2 Signal processingThe
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Batch cycle processing 1856.1.3 Batch cycle pro
186 Acquisition modeSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev USmoothingThe Daniel Mark II
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Chord gas and sound velocity measurements 1876.
188 Average sound velocitySection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UFor all other port an
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Average sound velocity 189Optional AGA10 sound
190 Average weighted gas flow velocitySection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U6.1.7 Ave
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Average weighted gas flow velocity 191Equation
192 Average weighted gas flow velocitySection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UIn the ev
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Calibration 1936.1.8 CalibrationThe Daniel Mark
xiv List of FiguresList of Figures Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UFigure 3-11 Ground lug upper electronic
194 CalibrationSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UEquation 6-9 Wet-calibration ga
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Calibration 195Third-order polynomialIf the thi
196 Volumetric flow rateSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U6.1.9 Volumetric flow r
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Volumetric flow rate 197Equation 6-13 Flow-con
198 Volumetric flow rateSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UEquation 6-15 Pressure
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Volumetric flow rate 199Profile-effect correcti
200 Volumetric flow rateSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UEquation 6-18 Reynolds
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Volume 201Equation 6-19 Base-condition volumet
202 Triggered Delta VolumesSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U6.1.11 Triggered Del
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Energy rate and totals 203Read delta volume reg
Reference, Installation, and Operations Manual List of Figures3-9000-743 Rev U August 2014List of Figures xvFigure 5-16 Field Setup Wizard - Gas Chr
204 Mass rate and totalsSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UThe energy rate validit
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Seniorsonic flow characterizations 205The mass
206 Flow-condition pressure and temperatureSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UProf
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Flow-condition pressure and temperature 207Data
208 Flow-condition pressure and temperatureSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UThe
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Flow-condition pressure and temperature 209On t
210 Gas propertiesSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U6.1.16 Gas propertiesGas prop
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Gas properties 211 Table 6-7 Fixed gas compos
212 Gas propertiesSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev ULive (GC) gas property dataTh
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Gas properties 213The validity of the GC-read g
xvi List of FiguresList of Figures Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UFigure 7-21 Microsoft® Excel charts vie
214 Gas propertiesSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UThe fixed gas component data
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014AGA8 compressibility calculations 2156.1.17 AGA
216 Frequency outputsSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UFrequency data contentEach
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Frequency outputs 217Frequency value data point
218 Frequency outputsSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UFrequency test modeThe Mar
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Digital outputs 2196.2.2 Digital outputsThe fol
220 Digital outputsSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UDigital output test modeThe
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Analog (Current) output 2216.2.3 Analog (Curren
222 Analog (Current) outputSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UVelocity content out
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Analog (Current) output 223Outputs test modeThe
Reference, Installation, and Operations Manual Section 1: Introduction3-9000-743 Rev U August 2014Manual overview 111 Section 1: Introduction1.1 Ma
224 Analog (Current) outputSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev Ube set from 0 to 150
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Digital Input 225The maximum length of time tha
226 Modbus communicationSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U6.4 Modbus communicatio
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Log record access 2276.4.2 Log record accessDue
228 Hardware configurationSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U6.5.1 Hardware config
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Data polling 2296.5.4 Data pollingThe meter per
230 GC data validitySection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U6.5.5 GC data validityThe G
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Archive logs 2316.6 Archive logsThe Mark III me
232 Daily logSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UThe data points included in the da
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Daily log 233PrevDayMacro1*:Macrobit 31bit 30bi
2 Definitions, acronyms, abbreviationsSection 1: Introduction Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U1.2 Definiti
234 Daily logSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev USndVelA,SndVelB,SndVelC,SndVelDFlo
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Daily log 235MethaneInUseN2InUseCO2InUseEthaneI
236 Hourly logSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U6.6.2 Hourly logThe Mark III mete
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Hourly log 237RhoMixFlow*Flow-GatedZFlow*Flow-G
238 Hourly logSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UPrevDayMacro2*:Macrobit 31bit 30b
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Audit log 2396.6.3 Audit logThe Mark III meter
240 Audit logSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UReference, select the Index tab, s
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Audit log 241Calibration AvgDlyA ... AvgDlyDCal
242 Audit logSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UExpansion CorrectionEnableExpCorrP
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Audit log 243DO2AContent ... DO2BContentDO2AIsI
Reference, Installation, and Operations Manual Section 1: Introduction3-9000-743 Rev U August 2014Definitions, acronyms, abbreviations 3ft feet (len
244 Audit logSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U(With Series 100 Plus Board) IsAO2
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Audit log 245GC Interface GasPropertiesSrcSelGa
246 Audit logSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UMeterSerialNumber(With Series 100
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Audit log 247Pressure & Temperature Atmosph
248 Audit logSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev USignal ProcessingBatchPercentSmoot
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Audit log 249Determining meter power-up and pow
250 Alarm logSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U6.6.4 Alarm logThe Mark III meter
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Alarm log 251AvgFlowMeterMaxNegVel MeterMaxVelG
252 Alarm logSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UAreGasPropertiesInvalidGC TRUEAreG
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014System log 2536.6.5 System logThe Mark III mete
4 Definitions, acronyms, abbreviationsSection 1: Introduction Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev Um3/hcubic me
254 Reading log recordsSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev Ulog type. Select whether
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Viewing transducer waveforms 2556.7 Viewing tra
256 Power disruption during firmware upgradeSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UNor
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Power disruption during firmware upgrade 257You
258 Self-tests and data reliabilitySection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U6.9 Self-tes
Reference, Installation, and Operations Manual Section 6: Meter operation3-9000-743 Rev U August 2014Log transfer integrity 259The Mark III meter fi
260 Configuration dependency checksSection 6: Meter operation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014Field hydrostatic pressure testi
262 T-Slot Transducer Removal and Installation ProceduresSection 7: Maintenance and troubleshooting Reference, Installation, and Operations ManualAu
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014Removal with Extractor Tool 263
Reference, Installation, and Operations Manual Section 1: Introduction3-9000-743 Rev U August 2014What’s new 51.3 What’s newDaniel MeterLinkThis ver
264 Removal with Extractor ToolSection 7: Maintenance and troubleshooting Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014Removal without Extractor Tool
266 Removal without Extractor ToolSection 7: Maintenance and troubleshooting Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Re
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014Installing the transducers 2677
268 Installing the transducersSection 7: Maintenance and troubleshooting Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U5
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014Installing the transducers 2699
270 Replace the transformersSection 7: Maintenance and troubleshooting Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U12.
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014Modifying the Calibration Parame
272 Replacing the Mark III ElectronicsSection 7: Maintenance and troubleshooting Reference, Installation, and Operations ManualAugust 2014 3-9000-74
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014Troubleshooting Communications
Daniel customer serviceE-mail• Customer Service: [email protected]• Customer Support: [email protected]• Asia-Pacific: dan
6 Daniel Ultrasonic Meter reference manualsSection 1: Introduction Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U Contin
274 Maintenance log files and trend filesSection 7: Maintenance and troubleshooting Reference, Installation, and Operations ManualAugust 2014 3-9000
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014Maintenance log files and trend
276 Daniel MeterLink fails to connect or crashes using Windows® 2000Section 7: Maintenance and troubleshooting Reference, Installation, and Operatio
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014Windows® Hotfixes — Obtaining Ho
278 Troubleshooting Meter StatusSection 7: Maintenance and troubleshooting Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014System Alarm 279 Figure 7-13
280 Chord A to Chord DSection 7: Maintenance and troubleshooting Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U7.5.3 Cho
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014Maintenance logs and reports 28
282 Collecting logs and viewing Excel reportsSection 7: Maintenance and troubleshooting Reference, Installation, and Operations ManualAugust 2014 3-
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014Collecting logs and viewing Exce
Reference, Installation, and Operations Manual Section 1: Introduction3-9000-743 Rev U August 2014References 71.5 References[1]Gould Modbus Protocol
284 Collecting logs and viewing Excel reportsSection 7: Maintenance and troubleshooting Reference, Installation, and Operations ManualAugust 2014 3-
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014Collecting logs and viewing Exce
286 Collecting logs and viewing Excel reportsSection 7: Maintenance and troubleshooting Reference, Installation, and Operations ManualAugust 2014 3-
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014Collecting logs and viewing Exce
288 Collecting logs and viewing Excel reportsSection 7: Maintenance and troubleshooting Reference, Installation, and Operations ManualAugust 2014 3-
Reference, Installation, and Operations Manual Section 7: Maintenance and troubleshooting3-9000-743 Rev U August 2014Collecting logs and viewing Exce
290 Collecting logs and viewing Excel reportsSection 7: Maintenance and troubleshooting Reference, Installation, and Operations ManualAugust 2014 3-
Reference, Installation, and Operations Manual Conversion factors3-9000-743 Rev U August 2014Conversion factors per unit of measurement 293A CONVERS
294 Conversion factors per unit of measurementConversion factors Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Miscellaneous equations3-9000-743 Rev U August 2014Miscellaneous conversion factors 295AAppendix B M
8 ReferencesSection 1: Introduction Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
296 Miscellaneous conversion factorsMiscellaneous equations Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UVolumetric Flo
Reference, Installation, and Operations Manual Miscellaneous equations3-9000-743 Rev U August 2014Chord “L” dimension calculation 297B.2 Chord “L” d
298 Chord “L” dimension calculationMiscellaneous equations Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Upgrading a Mark II to a Mark III3-9000-743 Rev U August 2014Meter electronics upgrade 299AIAppendix
300 What’s new In Mark IIIUpgrading a Mark II to a Mark III Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U• SENIORSONIC™
Reference, Installation, and Operations Manual Upgrading a Mark II to a Mark III3-9000-743 Rev U August 2014What’s new In Mark III 301• FEWER BOARDS
302 Modbus CommunicationUpgrading a Mark II to a Mark III Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UC.3 Modbus Commu
Reference, Installation, and Operations Manual Upgrading a Mark II to a Mark III3-9000-743 Rev U August 2014Configuration conversion 303C.4 Configur
304 Metrology - calibration equation parametersUpgrading a Mark II to a Mark III Reference, Installation, and Operations ManualAugust 2014 3-9000-74
Reference, Installation, and Operations Manual Upgrading a Mark II to a Mark III3-9000-743 Rev U August 2014Metrology - calibration equation paramete
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Description 921Section 2: Product overview2.1
306 Metrology - calibration equation parametersUpgrading a Mark II to a Mark III Reference, Installation, and Operations ManualAugust 2014 3-9000-74
Reference, Installation, and Operations Manual Upgrading a Mark II to a Mark III3-9000-743 Rev U August 2014Gain 307C.4.3 GainThe Mark III signal ga
308 Emission rate, stacked emission rate, and firing sequenceUpgrading a Mark II to a Mark III Reference, Installation, and Operations ManualAugust
Reference, Installation, and Operations Manual Upgrading a Mark II to a Mark III3-9000-743 Rev U August 2014Inactive chords 309C.4.8 Inactive chords
310 Frequency output configurationUpgrading a Mark II to a Mark III Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UC.4.10
Reference, Installation, and Operations Manual Upgrading a Mark II to a Mark III3-9000-743 Rev U August 2014Flow pressure and temperature 311C.4.11
312 Log Format parametersUpgrading a Mark II to a Mark III Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Troubleshooting comm., mech., and elec.3-9000-743 Rev U August 2014Communications troubleshooting 313
314 Communications troubleshootingTroubleshooting comm., mech., and elec. Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Troubleshooting comm., mech., and elec.3-9000-743 Rev U August 2014MARK III mechanical/electrical trou
10 Advantages and FeaturesSection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U2.1.1 Advantages and
316 MARK III mechanical/electrical troubleshootingTroubleshooting comm., mech., and elec. Reference, Installation, and Operations ManualAugust 2014
Meter setup and configuration worksheet Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U 317 Meter setup and configuration
Meter setup and configuration worksheet 318 Reference, Installation, and Operations Manual Meter setup and configuration worksheet3-9000-743 Rev U Au
Meter setup and configuration worksheet Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U 319 Meter setup and configuration
Meter setup and configuration worksheet 320 Reference, Installation, and Operations Manual Meter setup and configuration worksheet3-9000-743 Rev U Au
Meter setup and configuration worksheet Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U 321 Meter setup and configuration
Meter to Flow Computer Communication Worksheet 322 Reference, Installation, and Operations Manual Meter setup and configuration worksheet3-9000-743 R
Meter setup and configuration worksheet Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U 323 Meter to Flow Computer Communi
Meter to Flow Computer Communication Worksheet 324 Reference, Installation, and Operations Manual Meter setup and configuration worksheet3-9000-743 R
Meter setup and configuration worksheet Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U 325 Meter to Flow Computer Communi
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Mechanical installation requirements 11• Detai
Meter to Flow Computer Communication Worksheet 326 Reference, Installation, and Operations Manual Meter setup and configuration worksheet3-9000-743 R
Meter setup and configuration worksheet Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U 327 Meter to Flow Computer Communi
Meter to Flow Computer Communication Worksheet 328 Reference, Installation, and Operations Manual Meter setup and configuration worksheet3-9000-743 R
Meter setup and configuration worksheet Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U 329 Meter to Flow Computer Communi
Meter to Flow Computer Communication Worksheet 330 Reference, Installation, and Operations Manual Meter setup and configuration worksheet3-9000-743 R
Reference, Installation, and Operations Manual Flow rate summary charts3-9000-743 Rev U August 2014Flow Rate Summary Charts 331ASAppendix F Flow ra
332 Flow Rate Summary ChartsFlow rate summary charts Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UFLOW RATES (MSCMH) BA
Reference, Installation, and Operations Manual Flow rate summary charts3-9000-743 Rev U August 2014Flow Rate Summary Charts 333Flow Rates (MMSCFD) B
334 Flow Rate Summary ChartsFlow rate summary charts Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev Ut of Engineering Draw
Reference, Installation, and Operations Manual Write-protected configuration parameters3-9000-743 Rev U August 2014Write-protected configuration 335
12 Daniel Mark III Ultrasonic Gas Flow Meters assemblySection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-7
336 Write-protected configurationWrite-protected configuration parameters Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Write-protected configuration parameters3-9000-743 Rev U August 2014Write-protected configuration 337
338 Write-protected configurationWrite-protected configuration parameters Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Write-protected configuration parameters3-9000-743 Rev U August 2014Write-protected configuration 339
340 Write-protected configurationWrite-protected configuration parameters Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Write-protected configuration parameters3-9000-743 Rev U August 2014Write-protected configuration 341
342 Write-protected configurationWrite-protected configuration parameters Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Write-protected configuration parameters3-9000-743 Rev U August 2014Write-protected configuration 343
344 Write-protected configurationWrite-protected configuration parameters Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Open source licenses3-9000-743 Rev U August 2014Open source licenses 345AAppendix H Open source licen
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Daniel Mark III Ultrasonic Gas Flow Meters asse
346 GNU General Public LicenseOpen source licenses Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UThe link below, to the
Reference, Installation, and Operations Manual Open source licenses3-9000-743 Rev U August 2014GNU General Public License 347GNU GENERAL PUBLIC LICE
348 GNU General Public LicenseOpen source licenses Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UThese restrictions tran
Reference, Installation, and Operations Manual Open source licenses3-9000-743 Rev U August 2014GNU General Public License 349GNU GENERAL PUBLIC LICE
350 GNU General Public LicenseOpen source licenses Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UYou may charge a fee fo
Reference, Installation, and Operations Manual Open source licenses3-9000-743 Rev U August 2014GNU General Public License 351These requirements appl
352 GNU General Public LicenseOpen source licenses Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U years, to give any
Reference, Installation, and Operations Manual Open source licenses3-9000-743 Rev U August 2014GNU General Public License 353 4. You may not copy,
354 GNU General Public LicenseOpen source licenses Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U 7. If, as a consequen
Reference, Installation, and Operations Manual Open source licenses3-9000-743 Rev U August 2014GNU General Public License 355to distribute software
14 Daniel Mark III Ultrasonic Gas Flow Meters assemblySection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-7
356 GNU General Public LicenseOpen source licenses Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev USoftware Foundation, wr
Reference, Installation, and Operations Manual Open source licenses3-9000-743 Rev U August 2014GNU General Public License 357How to Apply These Term
358 GNU General Public LicenseOpen source licenses Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UAlso add information on
Reference, Installation, and Operations Manual Open source licenses3-9000-743 Rev U August 2014BSD Open Source License 359H.1.2 BSD Open Source Lice
360 M.I.T. LicenseOpen source licenses Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UH.1.3 M.I.T. LicenseFor more detail
Reference, Installation, and Operations Manual Open source licenses3-9000-743 Rev U August 2014Mird License 361H.1.4 Mird LicenseLicenseThe Mird dat
362 Mird LicenseOpen source licenses Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U Reserved except as specified below.
Reference, Installation, and Operations Manual Engineering drawings3-9000-743 Rev U August 2014Ultrasonic Meter Drawings 363AAppendix I Engineering
364 Ultrasonic Meter DrawingsEngineering drawings Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Daniel Mark III Ultrasonic Gas Flow Meters asse
Reference, Installation, and Operations Manual Index3-9000-743 Rev U August 2014Manual Index 365A INDEX Appendix J IndexJ.1 Manual IndexAAbnormal P
366 Manual IndexIndex Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UConverting Mark II “BG” and “A” Polynomial Coefficie
Reference, Installation, and Operations Manual Index3-9000-743 Rev U August 2014Manual Index 367Frequency Test Mode...
368 Manual IndexIndex Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UOption Board General Status LED Indicators...
Reference, Installation, and Operations Manual Index3-9000-743 Rev U August 2014Manual Index 369SIM2251 mode ...
370 Manual IndexIndex Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Signal words and symbolsPay special attention to the following signal words, safety alert symbols and statements:ImportantImportant is a statement the
16 Daniel Mark III Ultrasonic Gas Flow Meters assemblySection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-7
P/N 3-9000-743 Rev U2014Daniel Measurement and Control, Inc. 11100 Brittmoore Park DriveHouston, TX 77041 USAT+1 713-467-6000F+1 713-827-4805USA Toll
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Model 3400 meter body 172.2.2 Model 3400 meter
18 Model 3422 meter bodySection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U2.2.3 Model 3422 meter
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Model 3410 meter body 192.2.4 Model 3410 meter
20 Model 3420 meter bodySection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U2.2.5 Model 3420 meter
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Transducers and cabling 212.2.6 Transducers an
22 General unit specificationsSection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U2.3 General unit
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Flow range limits 232.3.4 Flow range limitsThe
24 Flange typesSection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U2.3.5 Flange typesThe meter bod
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Electronic specifications 252.4 Electronic spe
Important safety instructionsDaniel Measurement and Control, Inc. (Daniel) designs, manufactures and tests products tofunction within specific conditi
26 Hardware featuresSection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U2.5 Hardware features2.5.1
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Outputs 27Each group has a separate ground (i.
28 OutputsSection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UCable length open collector modeFor
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Status Indicators 29Analog output(s)A 4-20 mA
30 Status IndicatorsSection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UFigure 2-15 Mark III CPU
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Status Indicators 31CPU Board Communication St
32 Status IndicatorsSection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U Option Board General Stat
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Status Indicators 33Series 100 Plus Option Boa
34 Status IndicatorsSection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev USeries 100 Plus Option Boa
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Communications 352.6 CommunicationsThe Daniel
Product Operation Personnel:• To prevent personal injury, personnel must follow all instructions of this manual prior to and during operation of the p
36 CommunicationsSection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UWhen Belden wire No. 9940 or
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014Safety 372.7 SafetyThe Daniel 3400 Series Gas
38 INMETRO CertificationsSection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UFigure 2-23 Mark III
Reference, Installation, and Operations Manual Section 2: Product overview3-9000-743 Rev U August 2014FCC Compliance 392.8 FCC ComplianceThis equipm
40 FCC ComplianceSection 2: Product overview Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Installation instructions 393Section 3: Installati
40 Installation instructionsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UThis section discusses
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Daniel 3400 Series Ultrasonic Flow Meter lifting in
42 Daniel 3400 Series Ultrasonic Flow Meter lifting instructions and precautionsSection 3: Installation Reference, Installation, and Operations Manu
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Use of appropriate safety engineered swivel hoist r
NoticeTHE CONTENTS OF THIS PUBLICATION ARE PRESENTED FOR INFORMATIONAL PURPOSES ONLY, AND WHILEEVERY EFFORT HAS BEEN MADE TO ENSURE THEIR ACCURACY, TH
44 Safety precautions using safety engineered swivel hoist ringsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Safety precautions using safety engineered swivel h
46 Safety precautions using safety engineered swivel hoist ringsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014How to obtain safety engineered swivel hoist rings
48 Using appropriately rated lifting slings on Daniel Ultrasonic MetersSection 3: Installation Reference, Installation, and Operations ManualAugust
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Using appropriately rated lifting slings on Daniel
50 Using appropriately rated lifting slings on Daniel Ultrasonic MetersSection 3: Installation Reference, Installation, and Operations ManualAugust
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Mechanical installation 513.3 Mechanical installat
52 Meter body installationSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UFor bi-directional flow,
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Mounting requirements for heated or cooled pipeline
Warranty and Limitations1. LIMITED WARRANTY: Subject to the limitations contained in Section 2 herein, Daniel Measurement &Control, Inc. (“Daniel”
54 Accessing the Daniel 3400 Series Ultrasonic Flow Meter componentsSection 3: Installation Reference, Installation, and Operations ManualAugust 201
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Accessing the Daniel 3400 Series Ultrasonic Flow Me
56 Accessing the Daniel 3400 Series Ultrasonic Flow Meter componentsSection 3: Installation Reference, Installation, and Operations ManualAugust 201
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Transducer cables/appropriate transducer 5712. Re-
58 For systems using explosion-proof conduitSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U3.3.5
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014For systems that use flame-proof cable 593.3.6 For
60 Wiring and ConnectionsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U3.4 Wiring and Connection
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Wiring and Connections 61Alternately, when using D
62 Wiring and ConnectionsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U Table 3-9 J3 Chassis G
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Wiring and Connections 63 Table 3-13 J12 Analog
Reference, Installation, and Operations Manual Table of Contents3-9000-743 Rev U August 2014Contents iContentsPrefaceDaniel customer serviceSignal w
64 Wiring and ConnectionsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U 1AIn1 + (Temperature)2AI
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Wiring and Connections 65 The default field conne
66 Hardware Switch SettingsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev U3.5 Hardware Switch Set
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Hardware Switch Settings 67Figure 3-17 Daniel 340
68 Hardware Switch SettingsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UFigure 3-18 Option Boa
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Hardware Switch Settings 69Figure 3-19 Series 100
70 Hardware Switch SettingsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UFigure 3-20 CPU Board
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Hardware Switch Settings 71Figure 3-21 Series 100
72 Hardware Switch SettingsSection 3: Installation Reference, Installation, and Operations ManualAugust 2014 3-9000-743 Rev UFigure 3-22 Series 100
Reference, Installation, and Operations Manual Section 3: Installation3-9000-743 Rev U August 2014Communication settings 73 Figure 3-23 Field Conn