6 Length of pause before dialing (ignore dial tone)
This register denotes the wait time (between 2 and 10 seconds)
before a blind dial, with no dial tone detection. The default value
is <n>=2 seconds.
The value of ATS6 is used when the ATX command is set to 1
or 3. ATX settings of 2 and 4 enable dial tone detection and
disable blind dialing. Therefore, when X is set to 2 or 4, the
value of S6 is ignored.
0–255 002 seconds
7 Wait time for connection
This register sets the limit, between 1 and 255 seconds, for how
long the modem will wait for a carrier signal from a remote
modem before hanging up. The default value is <n>=50
seconds.
1–255 060 seconds
8 Length of comma pause
This command is provided for compatibility reasons; no action
is taken by the modem. Parameters are ignored.
0–255 002 seconds
10 Carrier detection and carrier loss delay
Specifies how long the carrier from a remote modem can be
absent before the modem disconnects (between 0 and 255
seconds). Longer delays allow temporary disruptions to the
carrier without disconnecting. Shorter delays detect dropped
carriers more efficiently when the connection is good.
The default value is <n>=15 seconds. A setting of <n>=255
causes the modem to disable carrier detection and presume
the carrier is always present.
1–255 015 0.1 s
Table 3-10: S registers (cont.)